Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 113

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
3
Overview of IO-Link Data and Functions (continued)
3.5
System Commands
Command Value
Device Action
0x40 (64)
Teach Apply – Calculates the switching point for SP1, SP2.
0x41 (65)
Teach SP1 – Determines teach point 1 for setpoint 1 and calculates the switching point.
0x42 (66)
Teach SP2 – Determines teach point 1 for setpoint 2 and calculates the switching point
0x43 (67)
Teach SP1 TP1 – Determines teach point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2 – Determines teach point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1 – Determines teach point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2 – Determines teach point 2 for setpoint 2
0x47 (71)
Teach SP1 Start – Starts dynamic teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop – Stops dynamic teach-in for setpoint 1 and calculates the switching point.
0x49 (73)
Teach SP2 Start – Starts dynamic teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop – Stops dynamic teach-in for setpoint 2 and calculates the switching point
0x4E (78)
Teach Reset – The teach-in process is interrupted, the setpoints are reset to the default settings.
0x4F (79)
Teach Cancel – The teach-in process is interrupted.
0x80 (128)
Device Reset – Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values (see section 7.3 on page 75).
0x81 (129)
Application Reset (see chapter 7.3 on page 75)
0x82 (130)
Restore Factory Settings (see section 7.3 on page 75)
0xA5 (165)
Maintenance Reset (see chapter 7.3 on page 75)
0xA6 (166)
Switching Counter Reset – Resets counter value and flags.
0xA7 (167)
Statistics Reset – Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg – Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop – Stops statistics operation completely.
0xAA (170)
Signal Speed Monitoring Reset - Resets the speed value and flags.
0xAC (172)
Statistics Start Moving Average – Starts the statistics of the moving average calculation.
0xAF (175)
Start Device Discovery
0xC0 (192)
Set Reference Orientation – Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.
0xC1 (193)
Acknowledge User Parameter Reset – Acknowledge message and restore the correct device
parameters.
0xE0 (224)
Teach Preset – Sets the current measurement value to the value of Measurement Preset.
0xE1 (225)
Teach Lower Limit – Sets the lower end of the measuring range.
0xE2 (226)
Teach Upper Limit – Sets the upper end of the measuring range.
Tab. 3-3:
System Commands – Overview
www.balluff.com
english
21