Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 116

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
4
Communication parameters
The basic IO-Link specification of the standard variant
BFD 3SAP-19N000-U01-LA2-C... (BMSP) is described in
Tab. 4-1.
Specification
Transmission rate
Minimum cycle time of device
Frame specification:
– Number of on demand data Preoperate
– Number of on demand data Operate
– ISDU
IO-Link protocol version
Number of process data device to master
Number of process data master to device
Manufacturer ID
Device identification
Tab. 4-1:
Communication parameters
In order to flexibly adapt the basic communication
parameters to the application, other device variants can
also be adjusted (see Tab. 4-2 on page 24).
The following device variants can be selected (see also
chapter 7.4 on page 76):
Variant name
Device
identifier
BFD 3SAP-
0x030501 COM3
19N000-U01-
LA2-C... (BMSP)
BFD 3SAP-
0x030503 COM3
19N000-U01-
LA2-C... (CCM)
Tab. 4-2:
Communication parameters – Device variants
24
english
IO-Link Description
COM
min cycle time
M-Sequence Capability:
– Number of On-demand Data in
Preoperate
– Number of On-demand Data in
Operate
– ISDU supported
Revision ID
ProcessDataIn
ProcessDataOut
Vendor ID
Device ID
Transmission
Minimum
rate
cycle
time of
device
0x0E
(230.4 kBaud)
(1.4 ms)
0x0E
(230.4 kBaud)
(1.4 ms)
Value
COM3 (230.4 kBaud)
0×0E (1.4 ms)
0×1B
8 bytes
2 bytes
Supported
0×11 (Version 1.1)
0xC5 (6 bytes)
0×00 (0 Bit)
0×378
0x030501
Frame specification
IO-Link
(Number of
protocol
Preoperate on
version
demand data
required / Number
of Operate on
demand data
required / ISDU)
8 / 2 bytes
0×11
(Version 1.1)
8 / 2 bytes
0×11
(Version 1.1)
Qty. of process
data
Device
Master
to
to
master
device
0xC5
0×00
(6 bytes)
(0 Bit)
0xC9
0×00
(10 bytes)
(0 Bit)

Werbung