Secondary Device Functions (continued)
Speed Monitoring State
With Speed Monitoring State, the current status can be
read.
Value
Meaning
Description
0x00 (0)
Idle
No speed value yet available
0x01 (1)
Too low
Speed value is less than the
lower threshold
0x02 (2)
OK
Speed value is in the suitable
range
0x04 (4)
Too high
Speed value is greater than
the upper threshold
0x08 (8)
Startup
Startup delay currently
Delay
running
0xFF (255)
Deactivated
Feature is deactivated
Tab. 6-11: Signal Speed Monitoring – Speed Monitoring State
Speed Monitoring Value
With Speed Monitoring Value, the current speed value can
be read.
6.2.5
System Commands
Command
Device Action
Value
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Restore Factory Settings – Resets
writable parameters to the default value.
0xAA (170)
Signal Speed Monitoring Reset - Resets
the speed value and flags.
Tab. 6-12: Signal Speed Monitoring – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
6.2.6
Events
Event Code
Event Type
0x8D08 (36104)
Warning
0x8D09 (36105)
Warning
Tab. 6-13: Signal Speed Monitoring –Events
6.2.7
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Event – Description – Remedy
Speed value is below the limit.
Speed value is above the limit.
Device Status
0 – Device is operating properly.
0 – Device is operating properly.