BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
5
Primary Device Functions (continued)
5.5.4
ISDU
Name
Low Signal Quality Threshold
Signal Quality
Current Signal Quality
Signal Quality Bad
Tab. 5-25: Signal quality – ISDU
Low Signal Quality Threshold
The threshold value for low signal quality can be set in
order to monitor the current signal quality. It is displayed as
a value between 0 and 100 in percent. If the current signal
quality value drops below the signal quality threshold value,
the Low Signal Quality Level warning is output.
The function can be deactivated by setting the threshold
value to zero.
Current Signal Quality
The current signal quality is displayed as a value between
0 and 100 in percent. If no valid signal quality is available,
the value is set to 255.
Signal Quality Bad
The status of the signal quality is displayed as a Boolean
value. If the value is TRUE, the signal quality is below the
threshold value; if the value is FALSE, the signal quality is
equal to or greater than the threshold value. This status is
visualized by an orange LED that illuminates if the value is
TRUE.
www.balluff.com
Index
Subindex
0x00CE (206)
0
0x00CF (207)
0
1
2
Access
Length
Data Type
R/W
1 byte
UINT8
R
2 bytes
R
1 byte
UINT8
R
1 Bit
BOOL
Data
Default
Storage
Yes
0
n/a
n/a
n/a