Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 134

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
5
Primary Device Functions (continued)
5.5.5
System Commands
Command
Device Action
Value
0x81 (129)
Application Reset – Sets the threshold
value with ISDU index 0xCE Low Signal
Quality Threshold to default 0. The
feature is thereby deactivated and the
evaluation of index 0xCF subindex 2
always results in FALSE.
0x82 (130)
Restore Factory Settings – Sets the
threshold value with ISDU index 0xCE
Low Signal Quality Threshold to default
0. The feature is thereby deactivated
and the evaluation of index 0xCF
subindex 2 always results in FALSE.
Tab. 5-26: Signal quality – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.5.6
Events
Event
Event
Event –
Code
Type
Description
– Remedy
0x8CFF
Warning
Low signal quality
(36095)
level
Tab. 5-27: Signal quality – Events
5.5.7
Variant Dependence
The functionality is available in all variants.
42
english
Device
Status
0 – Device is
operating
properly.