Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 126

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
5
Primary Device Functions (continued)
SSC X Configuration
This ISDU is used to configure the SSC. It is possible to
set the switching logic, switching mode as well as the
hysteresis.
If the switching mode is changed, the setting of the
setpoint parameter can be adjusted:
If changing from Two-Point or Window Mode to Single-
Point Mode, setpoint 2 is set to 0x7FFFFFFC and
thereby deactivated. In this state or in this setting, the
setting of setpoint 2 cannot take on any other value.
If changing from Single-Point Mode to Two-Point oder
Window Mode, setpoint 2 is again activated and set to
the value of setpoint 1 minus the minimum hysteresis
and, in the subsequent process, can be taught to a
different value.
Value
Meaning
Switchpoint Logic
0x00 (0)
High Active
0x01 (1)
Low Active
Switchpoint Mode
0x00 (0)
Deactivated
0x01 (1)
Single Point
0x02 (2)
Window
0x03 (3)
Two Point
Switchpoint Hysteresis
0x0032...
0x03E8
(50...1000)
Tab. 5-10: Switching profiles – SSC Configuration Logic
34
english
Description
Switching channel
deactivated
Single-Point Mode (SP1
activated)
Window Mode (SP1 +
SP2 activated)
Two-Point Mode (SP1 +
SP2 activated)
– Minimum:
100 (0x0064)
– Maximum:
1000 (0x03E8)
– Default: 150 (0x0096)
The hysteresis is used as
an integer offset to the
switching point value.
5.3.4
System Commands
Command
Device Action
Value
0x40 (64)
Teach Apply – Calculates the
switching point for SP1, SP2.
0x41 (65)
Teach SP1 – Determines teach
point 1 for setpoint 1 and calculates
the switching point.
0x42 (66)
Teach SP2 – Determines teach
point 1 for setpoint 2 and calculates
the switching point1)
0x43 (67)
Teach SP1 TP1 – Determines teach
point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2 – Determines teach
point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1 – Determines teach
point 1 for setpoint 21)
0x46 (70)
Teach SP2 TP2 – Determines teach
point 2 for setpoint 21)
0x47 (71)
Teach SP1 Start – Starts dynamic
teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop – Stops dynamic
teach-in for setpoint 1 and calculates
the switching point.
0x49 (73)
Teach SP2 Start – Starts dynamic
teach-in for setpoint 21)
0x4A (74)
Teach SP2 Stop – Stops dynamic
teach-in for setpoint 2 and calculates
the switching point1)
0x4E (78)
Teach Reset – The teach-in process
is interrupted, the setpoints are reset
to the default settings.
0x4F (79)
Teach Cancel – The teach-in process
is interrupted.
1) Available for LSSC if the currently set mode supports 2 setpoints.
Tab. 5-11: Switching profiles – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.3.5
Events
Event
Event
Event – Description
Code
Type
– Remedy
0x8DC0
Notifica-
Teach-in Timeout –
(36288)
tion
The current teach-in
process took too long
and was interrupted.
Tab. 5-12: Switching profiles – Events
Device
Status
0 – Device
is opera-
ting
properly.