38 | ACS 661 | Initial Setup
4.8

Edit Print Header

This ACS 661 has the capability to store recovery, vacu-
um, charge, and flush information for up to 20 vehicles.
The information loaded into Edit Print Header will ap-
pear on each printout. If you want to add a printer to
your ACS 661, refer to Printer Installation in the Mainte-
nance section of this manual.
1. Enter text by using the arrows and the multi-tap
interface on the numeric keypad:
R
Left arrow acts as a backspace key.
R
Right arrow moves the cursor to the right.
R
Zero (0) key acts as a spacebar.
R
Up and Down arrows navigate between the rows.
2. Press F1 to continue; press F2 to return to the previ-
ous header.
i
To update an existing language or to add a new
language, refer to Load Language in the Maintenance
section of this manual.
4.9

Service Vacuum

At this point the ACS 661 clears its internal plumbing
before proceeding with setup.
1. Check the vacuum pump oil level sight glass and
verify the oil level is at the center of the sight glass.
1
Fig. 4:
Check vacuum pump oil level
1 Opening at the rear of ACS 661 to check the oil level through the
sight glass
2. When prompted, connect the service hoses from the
ACS 661 to their flush ports.
3. Open the service hose mount by turning the collars
clockwise.
4. Press F1.
"
The ACS 661 performs an internal clearing of its
plumbing, and then sounds an alarm when the process
is complete.
|
SP00D00171
2019-07-02
4.10

Tank Fill

This procedure transfers refrigerant from a source tank
to the internal storage vessel (ISV) in the ACS 661. The
maximum capacity of the ISV is 23 kg (50,7 lb). Use
arrow keys to move the cursor; use the keypad to enter
a value.
1. The ACS 661 displays fields for desired tank fill
amount, chargeable refrigerant, and the amount of
recoverable refrigerant within the internal storage
vessel.
2. Enter the desired tank fill amount.
i
Add at least 4 kg (8,0 lb) of refrigerant to ensure
enough is available for charging.
3. Connect the low-side (blue) hose to the liquid con-
nector on the source tank.
4. Open the low-side (blue) valve on the control panel.
5. Open the coupling valve on the hose by turning the
collar clockwise.
6. Open the source tank valve.
7. Position the source tank in such a way that liquid
refrigerant is supplied to the connection.
8. Press F1 to start the tank fill process.
"
The ACS 661 begins filling the internal storage vessel
(ISV). This process takes 15 – 20 minutes.
i
The ACS 661 stops when the designated amount of
refrigerant has been transferred to the ISV or when
the source tank is empty.
9. Follow the messages on the display screen.
10. Close the low-side (blue) valve on the control panel.
11. Close the hose coupling valve by turning the collar
counterclockwise.
12. Close the source tank valve.
13. Press F2 to return to the Setup Menu.
"
The ACS 661 is ready for operation.
i
It is necessary to complete the entire Initial Setup
sequence before using the station. If it is not com-
pleted, this initial setup sequence is repeated every
time the station is switched on.
i
There is no need to calibrate the scale; it is calibrat-
ed at the factory.
i
After the tank fill process is complete, the display
does not show the same amount as the programmed
fill level. The display shows the amount of refriger-
ant that is available for charging, which is approxi-
mately 3 kg less than the total amount of refrigerant
in the tank.