36 | ACS 661 | Introduction
3.5

Setup Menu Functions

Access the following functions by pressing the Menu
key and selecting Setup.
Functions
Description
Air Purge Info Displays internal storage vessel (ISV) pressure
and temperature. Use to check ISV for excessive
pressure.
Calibration
Use to verify internal scale calibration. Refer to
Check
Calibration Check in the Maintenance section of
this user manual.
Edit Print
Programs information that will appear on the
Header
printout each time a print function is used.
Filter Mainte-
The filter removes acid, particulates, and mois-
nance
ture from the refrigerant. To meet requirements,
it is mandatory to replace the filter after 150 kg
(331 lbs.) of refrigerant has been filtered.
This menu item displays the filter capacity re-
maining until the ACS 661 locks down and no
longer functions. Refer to Filter Maintenance in
the Maintenance section.
Flushes residual oil from the ACS 661's service
Flush Hoses
hoses to prepare for service of next vehicle.
Variables affect the accuracy of oil injection. Use
Oil Inject Ad-
this menu item to adjust the oil inject correction
just
factor when using very high or low viscosity oils,
or if the ACS 661 is operating in very high or low
ambient temperatures. Refer to Oil Inject Adjust
in the Maintenance section of the manual for in-
structions.
Production
For Bosch production use only.
Menu
Pump Main-
Displays the amount of time remaining until the
tenance
next vacuum pump oil change is needed. For
maximum vacuum pump performance, change
vacuum pump oil every time the filter is re-
placed. Refer to the Change Vacuum Pump Oil in
the Maintenance section.
Displays the amount of refrigerant recov-
Refrigerant
ered, charged, and replenished (for the life of
Management
the ACS 661), and filtered since the last filter
change.
Select Lan-
Select a language for screen prompts. English is
guage
the default language.
Service Menu For Bosch service center use only.
Program the ACS 661 to display units of mea-
Select Units
sure in kilograms or pounds. The default display
is kilograms.
|
SP00D00171
2019-07-02
Functions
Description
Program the ACS 661 for current date and time.
Set Date and
Time
System Flush Provides a method of removing oil by forcing liq-
uid refrigerant through an A/C system or compo-
nents of an A/C system. After flushing, the refrig-
erant is recovered by the ACS 661 and filtered
by the recycling circuit.
Displays the revision level of the software in the
System Infor-
ACS 661.
mation
Tank Fill
Use this Setup Menu item to transfer refrigerant
from a source tank to the ISV. The tank fill val-
ue may be adjusted up or down to suit the us-
er's needs. Refer to Tank Fill in the Maintenance
section.
Failure to register and activate the ACS 661
Unit Activa-
within 30 days of initial startup will cause the
tion
ACS 661 to lock out and no longer function.
Select this Setup Menu item and follow the
prompts before the trial period expires.
View Service
Displays vehicle information that was entered in-
Data
to the Enter Service Data screen. Vehicles are
displayed by date of service and VIN number.
The database stores 20 VIN entries.
Refrigerant
To store the amount of refrigerant recovered
Tracking
and charged for each vehicle. The display shows
five selection options:
R Display: to display the recovered and charged
refrigerant data.
R Print: to print all the data stored on the sta-
tion.
R Export data to SD: to export the report with
the amount of refrigerant recovered and
charged on the vehicle. The data is exported
via SD card, recommended size at least 2 GB
and formatted FAT (SD card not supplied).
The data is transferred as a .csv file.
R Erase all records: to delete all the data stored
on the station.
R Disable Tracking: to disable the refrigerant re-
port function.
Charge no
To enable or disable the pulsing charge.
pulse
Calibrate Air
To perform the air flow calibration.
Flow
Follow the messages on the display screen.