Herunterladen Inhalt Inhalt Diese Seite drucken

Parametertabelle (Main-Schaltschrank) - Carel HUMISONIC Technisches Handbuch

Vorschau ausblenden Andere Handbücher für HUMISONIC:
Inhaltsverzeichnis

Werbung

8. PARAMETERTABELLE (MAIN-SCHALTSCHRANK)

Fenster
Display-Meldung
UP/DOWN drücken, um das Info-Icon einzublenden. Enter drücken, um auf das Info-Schnellmenü zuzugreifen.
Info
i01
Humidifier size
Next wash
i02
Work hours counter
Machine hours counter
i03
Water level sensor state
i04
Dip-switch state
i05
Secondary 1 status
Secondary 1 op. hour counter
i06
Secondary 2 status
Secondary 2 op. hour counter
i07
Secondary 3 status
Secondary 3 op. hour counter
i08
Preheat probe
i09
Output request
Output signal
A.
On/Off Unit
A01
On/Off
Enable
Autotest
Manual wash
Max Prod
B.
Setpoint
B01
Setpoint
Limit
C.
Clock/ Scheduler
C01
Clock
Day
Date
Hour
C02
Clock
DST (daylight saving time):
Transition time
Start:
in
at
End:
in
at
C03
Scheduler
Enable scheduler ?
C04
Time bands (press Enter and UP/DOWN to check the box)
Day
D.
Main/Secondary
Secondary Manager
E.
Data logger
E01
Data logger
Hour
Date
F.
User
User menu
a.
Regulation
Fa01
Regulation
Regulation type
Unit of measure
Fa02
Regulation
Max Prod
Max Prod
Min Prod
Fa03
Regulation
Ambient probe
Anmerkungen
Def.
M.E.
0,5
kg/h
-
h
-
h
-
h
-
-
-
h
-
h
-
h
°C
-
%
-
V
No
-
Yes
-
No
-
100
%
Fa01=Regelung
50.0
rH % / °C
mit Fühler
90.0
rH %
Monday
day
01/01/2015
dd/mm/yy --/--/----
hh:mm
hh:mm
Enable
-
60
min
Last
-
Sunday
day
March
month
2.00
hour
Last
-
Sunday
day
October
month
3.00
ora
No
-
Monday
-
Time 1
hh/mm
Off
-
Humidity set point
%rH
Time 2
hh/mm
Off
-
Humidity set point
%rH
Time 3
hh/mm
Off
-
Humidity set point
%rH
Time 4
hh/mm
Off
-
Humidity set point
%rH
Time 5
hh/mm
Off
-
Humidity set point
%rH
Time 6
hh/mm
Off
-
Humidity set point
%rH
-
-
-
hour : min
-
dd : mm : yy 01 : 01 : 00
Probe rH%+limit
-
rH%
°C-Kg/h
100
%
100
%
10
%
Analog
-
31
Min.
Max.
Wertbeschreibung
0,5
18
Low
High
Low ¦ Work ¦ High
-50
90
0.0
100.0
0.0
10.0
No
Yes
No ¦ Yes
No
Yes
No ¦ Yes
No
Yes
No ¦ Yes
10
100
10.0
80.0
0
100.0
Monday
Sunday
-
--/--/----
dd/mm/yy
00:00
23:59
hh:mm
Enable
Disable
0
240
First
Last
First ¦ ...¦ Fourth¦ Last
Monday
Sunday
Monday ¦ ...¦ Sunday ¦ ***
January
--
January ¦ ... ¦ December ¦ - -
0.00
23.00
First
Last
First ¦ ...¦ Fourth¦ Last
Monday
***
Monday ¦ ...¦ Sunday
January
December
January ¦ ... ¦ December
0.00
23.00
No
Yes
No ¦ Yes
Monday
Sunday
Monday ¦ ...¦ Sunday
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
00:00
23:59
Off
On+Set
Off ¦ On ¦ On +Set
0
100
001
50
Nr. alarm
00:00
23:59
Time of alarm activation
01 : 01 : 00
Date of alarm activation
On/Off
Probe T+Limit
On/Off ¦ Ext.regulator ¦ Ext.
rH%
regulator+limit rH% ¦ Probe rH% ¦
probe rH%+Limit rH% ¦ Probe T ¦
Probe T+Limit rH%
°C-Kg/h
°F-lb/h
°C-Kg/h ¦ °F-lb/h
10
100
10
100
0
100
Analog
HYHU000000
Analog ¦ HYHU000000
"humiSonic ventilation" +0300063DE - rel. 1.4 - 25.10.2022
GER
Typ R/W
I
R
I
R
I
R
I
R
I
R
R
I
R
I
R
I
R
I
R
I
R
I
R
I
R
I
R
I
R
D
R/W
D
R/W
D
R/W
I
R/W
I
R/W
I
R/W
I
R
I
R/W
I
R/W
D
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
D
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R/W
I
R
I
R
I
R
I
R/W
D
R/W
I
R/W
I
R/W
I
R/W
D
R/W

Werbung

Inhaltsverzeichnis
loading