Inspection and maintenance

The type and level of wear depends to a large extent on the individual usage and operating
conditions. Any indicated intervals therefore are only valid for the corresponding approved con-
ditions.
Interval
Where?
Start of shift
After each
maintenance or
repair work
weekly
Every month
EN
DQ14 | DQ18 | DQ22
78
What?
How?
Examination for outside damages.

Safety check on page 54
Check if the clamping screws for the V-belt tension on the left
and right side of the drilling head are well fastened.
Check if the V-belts are well tightened. Checking the tension

of V-belts,
Lubricate the drill column regularly with commercial oil.
Lubricate the toothed rod regularly with commercial grease
(e.g. friction bearing grease).
Img. 6-1:
DQ22
Translation of original instruction
Speed variation on page 71.
Clamping screw right
Drill column
Toothed rod
Maintenance