are legible (clean them, if necessary)
are complete (replace if necessary).
INFORMATION
Organise the checks according to the following table;
General check
Equipment
Guards
Signs,
Markers
Date:
Functional check
Equipment
only on DQ22 - drill chuck guard
Emergency stop button
Position switch of protective cover 
V-belt
Date:
1.11

Emergency stop switch

CAUTION!
The drilling spindle keeps turning for a short time even after actuating the emergency
stop switch depending on the preset speed.

1.11.1 Drilling table

Seats for T-slots are attached to the clamping table.
WARNING!
Risk of injury due to workpieces flying off at high speed. Securely fix the workpiece on
the drilling table.
1.12

Separating protective devices

1.12.1 Drill chuck guard

Adjust the guard to the correct height before you start working. To do this, loosen the clamping
screw, set the required height and tighten the clamping screws again.

1.12.2 Protective cover of the V-belts

A protective cover for the belt pulleys is mounted on the drilling head. There is a switch inte-
grated in the protective cover which monitors that the cover is closed.
Safety
Version 1.0.3 - 2022-04-06
check
Mounted, firmly bolted and not damaged
Installed and legible
Checked by (signature):
check
After opening the drill chuck guard, the DQ22 drill
must switch off. The DQ22 drill must not start when
the chuck guard is open.
After actuating the emergency stop switch, the bench
drill must switch off.
The bench drill must not be switched on, if the
protective cover of the V-belts is opened.
Checked by (signature):
Translation of original instruction
OK
OK
DQ14 | DQ18 | DQ22
EN