Herunterladen Inhalt Inhalt Diese Seite drucken

Checking Function - Abicor Binzel ABIBUG 300 Originalbetriebsanleitung

Orbitalschweißautomat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Commissioning

6.11 Checking function

Risk of injury due to defective or damaged gas/or cable connections
If cable connections are installed incorrectly, there is a risk of injury or fatal electric shocks.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
Stunning of eyes by arcs
Arcs produced when testing can damage your eyes.
► Check and wear your personal protective equipment (eye protection).
EN - 32
WARNING
WARNING
Switch on the device at the On/Off switch.
1
The LED illuminates.
Ensure that the cable connections are correctly
2
seated/connected.
Check the locking elements (wire coil mandrel,
3
service lock, stop lever, running gear elements,
closed hood) and adjust if necessary.
Check the position of the welding torch and
4
bring it to the work position if necessary.
Check the LED status indication. The LED will
5
illuminate green.
 7.2.2 LED status indications on page EN-45
Press the <SHIFT> and <TRAV TEST> buttons on
6
the remote control and check the direction of
movement (CW/CCW).
Press the <CYCLE> button on the remote control.
7
Press the <STOP> button on the remote control to
8
terminate the functional check.
ABIBUG 300

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis