8 Decommissioning

Risk of burns from hot surface
Welding torches become very hot during welding. This may result in serious burns.
► Allow welding torches to cool down after welding.
► Wear the correct protective gloves.

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
Electric shock if contact is made with live parts
Live parts can cause fatal electric shocks.
► Only carry out maintenance work when the device does not carry any voltage. To do this, perform
► Switch off the device.
► Ensure the device cannot be switched on again.
► Check for zero voltage.
► Ground and short circuit the device.
► Cover or block off neighboring parts that are live.
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
WARNING
285 min.
400 min.
WARNING
the following measures:
WARNING
Press the <STOP> button. The welding process
1
ends.
Place the device in the desired position.
2
X
110
Switch on the device at the On/Off switch.
3
The LED illuminates.
Close the gas feed and disconnect the power
4
supply from the power supply unit.