Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Wire Filler Neck Set; Faults And Troubleshooting - Abicor Binzel ABIBUG 300 Originalbetriebsanleitung

Orbitalschweißautomat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ABIBUG 300

9.10 Replacing the wire filler neck set

Required tool:

10 Faults and troubleshooting

► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 8
Faults and troubleshooting
Fault
No welding current.
No ignition.
Cause
Distance from welding wire to workpiece
is too great.
Ground cable not connected.
Power source is not switched on.
Power source is defective.
Error in the electronics.
Error in the communications electrics.
Remote control defective.
10 Faults and troubleshooting
— AF10 fork wrench
Pull the lever and swing open the housing block.
1
Loosen the nut with a fork wrench AF10.
2
Disassemble the threaded sleeve, collet, nut,
3
and wire feed.
Mount again in reverse order.
4
Troubleshooting
► Readjust the welding torch.
 6.3 Mounting the welding torch – Z axis
on page EN-23
► Check the connection and connect if
necessary.
 6.9 Mounting the positioning belt on
page EN-32
► Check, and connect if necessary, the power
source.
 Observe the operating instructions for
the power source.
► 10.1 Error codes and causes on
page EN-65
► Check the remote control and replace if
necessary.
 6.4 Connecting the remote control on
page EN-25
EN - 55

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis