Herunterladen Inhalt Inhalt Diese Seite drucken

Testing The Function; Mounting Flexible Guide Rails (Optional) - Abicor Binzel ABICAR ADVANCED Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ABICAR ADVANCED:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Putting into operation

6.8 Testing the function

Flashing of the eyes due to arc
The arc generated during the test can damage your eyes.
► Check and wear your personal protective equipment (eye protection).
► To check whether the weld start signal cable is correctly connected, plug in the mains plug, switch on
the device and set the weld start signal switch to "Test".
 Fig. 3 Operating panel on page EN-10
The arc will ignite for a split second.

6.9 Mounting flexible guide rails (optional)

 14 Accessories on page EN-23
Required tool:
Magnetic block
EN - 18
WARNING
Butt joint
Lap joint
Internal hexagonal spanner SW3, SW4 and SW5
Allows movement on a surface and on tubes.
Max. rail length: 1.85 m
Min. bending radius: 1 m
Connect flexible guide rails to magnetic blocks with a
1
butt joint or lap joint.
Position magnets along the welding direction on the
2
workpiece.
Set the required distance on the adjustment tool.
3
Release the lever of the adjustment tool and place it on
4
the first magnet. Place the side of the stop pin against
the external edge of the material, or place the tip of
the stop pin in a groove.
Lock the lever of the adjustment tool.
5
Remove the remainder of the rail from the workpiece.
6
Move the adjustment tool along the guiding and
7
attach all magnets.
Disconnect standard guide arms from the device and
8
mount guide arms for flexible guide rails.
 6.3 Positioning guide arms on page EN-14
Hang the device with the guide arms in the flexible
9
guide rails.
ABICAR ADVANCED

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis