Electric shock due to defective cables
Incorrect cable and plug-in connections can lead to fatal electric shock.
► Use only 230 V cables or type G plugs.

6.6 Equipping the on-board wire feeder

Risk of crushing
Limbs can be crushed if device components are improperly equipped.
► Keep your hands out of the danger zone.
► Check and wear your personal protective equipment.
► Note a weight of approximately 5 kg when assembling and dissembling the wire spool.
WARNING
CAUTION
6 Commissioning
Connect the gas supply lines with the DN5
10
quick coupling.
Switch on the device at the On/Off switch.
11
The LED illuminates.
Push the machine safety switch <O> at
12
the power supply unit.
Check all plug-in and screw connections
13
for secure attachment.
Switch on the machine safety switch <I>.