6 Commissioning
6.1 Setting up the running gear
The running gear must be positioned on the positioning belt before assembly. Three running gear steps are
possible, depending on the pipe diameter to be welded.
Required tool:
6.2 Mounting the power and gas supply
Required tool:
EN - 20
— AF10 fork wrench
Rotate the device to the service position.
1
Loosen the screws (4× M6 ×16) using the socket
2
wrench (AF10) and remove them completely.
Select the corresponding hole, insert the screw
3
and tighten by hand.
Carry out the process for all four screws.
4
— AF19 fork wrench
— AF8 Allen key
Switch off the device at the On/Off switch.
1
The LED is extinguished.
ABIBUG 300