Tab. 9
Error codes and causes
Number
Module
2100
Travel
2101
Travel
2110
Travel
2111
Travel
2200
Travel
3001
Oscillation
3100
Oscillation
3101
Oscillation
3110
Oscillation
3111
Oscillation
3200
Oscillation
4000
Torsion
4200
Torsion
5200
Z axis
6200
Remote
7001
Power box
9000
Welder

11 Disassembly

Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
Follow the instructions described in Chapters 7 and 8 in reverse order to disassemble and dispose
of the device.
 6 Commissioning on page EN-20
 7 Operation on page EN-39
Dispose of the components in accordance with legal regulations.
 12 Disposal on page EN-67
Meaning
Encoder initialization
Read encoder
DRV8332 error message
DRV8332 temperature warning
CAN timeout
End switch reached the end position
Encoder initialization
Read encoder
DRV8332 error message
DRV8332 temperature warning
CAN timeout
Reference lost when switching on
CAN timeout
CAN timeout
CAN timeout
RTA timeout, 500 ms, no status received
Basis for power source errors (reserved for
Kemppi 255 numbers). See power source
documentation.
CAUTION
11 Disassembly
Troubleshooting
► Delete the error code by pressing the
<SHIFT> and <DOWN> buttons.
or
► Press reset for at least 5 seconds,
disconnect the device from the power and
then reconnect it.
or
► Check the connectors of the plates and,
if necessary, restore or replace them.
or
Replace the remote control.
EN - 59