16. BATTERY TEST

The expected life of the battery type used is
about 3 years. However, several factors can
affect battery life, such as:
Ambient temperature.
Humidity.
Long storage of the battery before it was used.
If the battery has been fully discharged for a
long period of time, it will never regain its full
capacity.

Checking the battery charging state

The battery charge level is automatically
checked every 7 days.
If configured accordingly, a battery alarm is
sent to an alarm receiver in the event of a
negative battery test.
Reset the alarm by pressing the reset button
after replacing the battery.
Battery test
If the reset button is pressed three times
within 2 seconds, a battery test is performed.
The battery test takes about 20 minutes.
If the battery level is low, the test is aborted.
In addition, if a relay is used, LED 2 and relay
"Battery failure" are activated. The battery
failure is activated with the help of parameter
*88*, see the corresponding parameter in the
parameter list.

Cancel battery test

Press the reset button once.
LED 2 stops flashing in red.
If the battery charge level falls below a certain
level (10.7 V), the dialling unit will not start
automatically. It must then be started by
pressing the reset key.

Test battery failure

Disconnect the battery plug while the battery
charge level is being checked.
The dialling unit triggers a battery alarm and
LED 2 and the battery alarm relay are acti-
vated (if configured accordingly).

Replace battery

Disconnect the 230 V power supply.
Replace the battery (suitable type: 1.2 A).

Main power supply failure

When properly configured, a power failure
alarm is sent to an alarm receiver 15 minutes
after the main power supply fails.