configurAtion StepS
*07*
0 to 6 #
*09*
0 or 1 #
*71*
0 or 1 #
*78*
0 to 2 #
*81*
00 to 16 #
82
Dialling unit settings
Radio network selection
Modem function
Buzzer
Display mode
Automatic call acceptance
Only relevant when using an LTE inter-
face circuit board (4G). In this case, it
is possible to specify which frequency
bands are to be used, or to which they
are restricted.
0 = 2G + 3G + 4G (Standard)
1 = 2G + 3G
2 = 2G + 4G
3 = 3G + 4G
4 = 2G
5 = 3G
6 = 4G
Press 0 to program via USB and 1 to
program via serial (RS232).
The buzzer sounds for incoming calls
or if the machine room telephone is
used.
0 = off
1 = on (default)
This parameter sets the display mode
for the pictograms (applies to all bus
units and relays if they are pro-
grammed for use with pictograms).
0 = default (default)
1 = strictly according to EN81-28
2 = strictly individual according to
EN81-28
Number of dial tones before the
dialling unit accepts an incoming call.
Pressing "00" will deactivate the auto-
matic call acceptance (call protection).
Please note: Active call protection is
not compliant to EN81-28.
00 = call is not accepted
01 = 1 dial tone
02 = 2 dial tone (default)
. . .
16 = 16 dial tone