Local Connection With Routine* And Without Protocol (Compliant To En81-28) - behnke AT6 Anleitung

Aufzugnotrutelefon
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Behnke AT6 manual
remote configurAtion uSing A telephone

Local connection with routine* and without protocol (Compliant to EN81-28)

1.
Start configuration:
2.
Local destination phone
number:
3.
Redundant
destination phone
number:
4.
Type of the 1st destination
phone number:
5.
Type of the 2nd destination
phone number:
6.
Emergency call button
delay
(3 seconds):
7.
Phone number for routine
test*:
8.
Routine tests every 3
days*:
9.
Record announcement for
emergency call (optional):
10. Display mode strictly
adhering to EN81-28
11.
Exit set-up mode:
*
Routine tests can also be manually triggered by an elevator attendant on site at least every three days. These must then also be
documented.
74
0 0
* 1 1 * 1 1 2 #
* 1 2 * 0 1 5 1 2 3 4 5 6 7 8#
* 2 1 * 1 #
* 2 2 * 1 #
* 8 7 * 0 3 #
* 1 7 * 1 1 3 #
* 2 7 * 3 #
* 5 1 * "Emergency call in
elevator x" #
* 7 8 * 1 #
* 0 0 * #
Internal destination phone
number ending on 112
Redundancy on emergency phone
No protocol (voice call only)
No protocol (voice call only)
Emergency call must be pressed
> 3 seconds
Other phone number to dis-
tinguish emergency call and
routine. (All test calls must be
documented and responded to if
missed)
Must be no longer than 3 days
apart
Announcement for emergency
call recipient, if there is no other
possibility for automatic assign-
ment.
Emergency call state must be
terminated with reset or key 5