configurAtion StepS

12. CONFIGURATION STEPS
Parameter
Value
*11*
#
*12*
#
*13*
#
*14*
#
*72*
01 to 99 #
*75*
0 or 1 #
*79*
1 to 5 #
*83*
0 or 1 #
*86*
0 or 1 #
76
Function
Emergency call settings
1. Destination phone number
2. Destination phone number
3. Destination phone number
4. Destination phone number
Waiting for call acceptance
Hotline function
Maximum call duration
Detect dial tone
Interrupt emergency call
Comment
Phone number of the alarm receiver
(1-20 digits). When calling from an
extension, the delay can be set by
adding asterisks (*). Each asterisk
corresponds to one second of delay at
the corresponding position. To delete,
enter hashtag without digits. For exam-
ple: *11*#.
Example for outside line access with
"0": *11*0**1234567#
Number of dial tones before dialling the
next phone number (default = 08)
The elevator telephone establishes
a direct connection to a specified
recipient without dialling a telephone
number for this purpose.
0 = normal telephone line (default)
1 = hotline
Maximum call duration in minutes for
LANGUAGE (default: 5 minutes). Other
protocols are always set to 8 minutes by
factory default
Automatic dial tone detection is active
by factory default and can be deacti-
vated in case of detection problems.
0 = off
1 = on (default)
Disconnects an emergency call lasting
longer than 60 seconds when the emer-
gency call button is activated again
and calls the next destination phone
number.
0 = off
1 = on (default)