led indicAtion And function of the reSet Button

6. LED INDICATION AND FUNCTION OF THE RESET BUTTON
ON THE DIALLING UNIT

LED 1 indicates the power supply status

To turn off the dialling unit in battery mode (with the power supply disconnected) without discon-
necting the battery, press and hold the reset button for 5 seconds. (Please note! The dialling unit
will not start if only the battery is connected)

LED 2 indicates active alarm and battery status

An active alarm (emergency call) can be reset or terminated by the rescuer on site by briefly press-
ing the reset button once. To start a self-test (battery and bus initialization), the reset button must
be pressed three times in succession within 2 seconds.
66
Green light
Flashes in red
Red light
Light off
Quickly flashes in
yellow
Flashes in red
Red light
Main power supply OK
Battery operated, emergency light is powered by mains
Battery operated, emergency light is not supplied by
mains
No active alarm and battery status OK
Alarm not reset (active emergency call state)
Battery test is running
Battery test negative or no battery connected