Herunterladen Inhalt Inhalt Diese Seite drucken

behnke AT6 Anleitung Seite 78

Aufzugnotrutelefon
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Behnke AT6 manual
configurAtion StepS
*17*
#
*19*
#
*27*
00 to
99 #
*31*
0.3 or 4 #
*16*
#
*30*
0 or 3 #
*39*
0 or 1 #
*84*
0 to 2 #
78
Routine tests
Destination phone number for
the test
Manual callback test
Days between tests
Type of routine test
LMS (Lift Monitoring System)
Destination phone number for
LMS
LMS message type
Message repetition
Message via emergency call
Phone number of the alarm receiver
for routine test call.
Triggers a test call to the entered
phone number.
Number of days between routine tests.
Always enter two digits. To deactivate
test "00".
Maximum 3 days according to EN81-
28: *27*03#
Protocol of the routine test call.
0 = P100
3= CPC
4 = CLIP (use phone number for iden-
tification)
Telephone number of the alarm
receiver for monitoring.
The protocol for elevator monitoring
(LMS).
0 = P100
3 = CPC (Battery alarm only)
LMS messages (faulty battery, bus unit
or button) are sent either only once
upon the first occurrence (parameter
set to 0 = default) or repeated every
24 hours (parameter set to 1).
Select which message(s) will be sent
to the recipient in the event of an
emergency call.
0 = none (default)
1 = Emergency call start
2 = Emergency call start and end