Emergency call state (parameter "0", default for relay 1)
▸
Relay is activated when the set time is reached.
▸
Relay is deactivated when the emergency call ends.
Battery failure (parameter "1", default for relay 2)
▸
Relay is activated when the battery test has failed.
▸
Relay is deactivated by pressing the reset key.
Yellow pictogram (parameter "2", applies only to relay 1)
▸
Relay is activated when the emergency call button is pressed (yellow pictogram)
▸
Relay is deactivated when the reset button is pressed or when the alarm centre sends DTMF tone
"5" (emergency call end).
Green pictogram (parameter "2" applies only to relay 2)
▸
Relay is activated when the call is answered or acknowledged (green pictogram).
▸
Relay is deactivated when the call is ended.
Activate using DTMF 8 (parameter "3" applies only to relay 1)
▸
Relay is activated for 5 seconds when key "8" (send DTMF tone) is pressed.
Activate using DTMF 9 (parameter "3" applies only to relay 2)
▸
Relay is activated for 5 seconds when key "9" (send DTMF tone) is pressed.
Manual reset (parameter "4")
▸
Relay is activated when the set time is reached.
Emergency call failure (parameter "5")
▸
Relay is activated if the emergency call could not be placed after max. 12 attempts (all 4 phone
numbers were dialled three times): "Emergency call failed".
System error (parameter "6")
▸
Relay is activated if power supply (230VAC) and PSTN/GSM network are ok.
▸
Relay is deactivated if power supply is lost for more than 15 minutes or GSM network is missing.
Emergency horn (parameter "7")
▸
Relay is activated if the "Emergency horn" output is active.
▸
Relay is deactivated if the "Emergency horn" output is deactivated.