5. Operating limits

max. engine speed r.p.m.
min. coolant temperature [°C / °F]
max. coolant temperature [°C / °F]
Note:
Warning: The engine is only allowed to be run at peak performance after reaching the
Note:
Warning: The maximum operating temperature of the engine must not be exceeded. If
Note:

6. Engine start and operation

6.1. Engine start and operation
Prior to engine start, verify the following:
At engine start proceed as follows:
Seite/page 89/100
Downloaded from
www.Manualslib.com
Operating Instructions 125 MAX DD2
Speed is limited electronically during kart operation to a maximum of 13.800 r.p.m.
specified operating temperature. Operating the engine at too low a
temperature could result in piston seizure.
If the engine does not reach the minimum specified operating temperature due to
the low ambient temperature, then the cooling efficiency of the radiator must be
reduced by partially covering the radiator with adhesive tape.
the temperature is too high, it may result in piston seizure.
Dirt must be cleared from the lamination of the radiator at regular intervals to
achieve the best cooling performance.
Fuel tank full.
Battery charged and connected.
Battery voltage over 12V
Carburetor Bowden cable is moving freely and carburetor piston connected in idle
position.
Shifting device in "Neutral" (no gear engaged)
On a cold engine pull the choke lever (Pos. 1) into a vertical position. (Fig. 20)