Logbook and flushing protocol
Ill.: 6.6.5: Opening the CSV log file dialogue
The KHS Mini Control System have a
facility to be used as measuring instru-
ments. To do this, the Control System that
are connected to a sensor, as described in
Chapter 6.3, are configured. Use the „Da-
talogging" function to generate, delete
and save the recorded measurement data
records in the form of a CSV file on the
PC. Up to 12 million lines can be backed
164 / 259 – K410068602008-00 / 09.2020 – © www.kemper-olpe.de
3
4
These buttons can be used to open and
save either the logbook or the flushing
log. The logbook (event log) documents
the water exchange procedures, error
messages and parameter changes per-
formed by the KHS mini system control.
The flushing log documents all the
measuring and flushing parameters.
up. Click the
CREATE LOGFILE
generate the current CSV file, which is not
yet completely full. Click the CSV file to
open a dialogue as shown in Fig. 6.6.6.
Here you can select whether the flushing
log should be saved or immediately ope-
ned. Use the
button to open a query as
shown in Fig. 6.6.7. Click OK to delete the
selected file.
button to