(6) Perform similar actions for other
sub-groups.
5 Shared radio group is in operation.
f To verify, perform the connection
test (see chapter 6.7 "Shared group
connecting test" on page 68).
6.6 Group connection test
You can check the correct connection of
a group (radio groups or a shared radio
group) as follows:
(1) Press and hold testing / stop button
of any device of the group for
approx. 12 seconds.
Short acoustic signal, single device
Short acoustic signal, single device
(2) Release testing / stop button.
Short acoustic signal, single
device and all other devices
in the radio group
5 Successful connection test of the
single device and the radio group.
68
Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
When a device within the radio
group is defective, the device
triggering the alarm and all
available devices sound an alarm
signal. The defective device stays
silent and can thus be identified
(see chapter 12 "Alarm and alert
tones" on page 80).
6.7 Shared group connecting test
You can check the correct connection of a ra-
dio group to a shared radio group as follows:
Only possible with subgroup
devices.
(1) Press and hold testing / stop button
of any device of the subgroup
pressed for approx. 60 seconds.
Short acoustic signal, single device
Short acoustic signal, single device
Short acoustic signal, single device