196 / 334
Bosch Rexroth AG
General notes regarding damage to property and products
3.3
Electrical connection
Incorrect voltage supply
Possibility of damage to the electrical equipment!
Check whether the supply voltage coincides with the nominal vol
"
tage indicated on the nameplate of the product!
The product may only be connected to the mains if these values
coincide.
Make sure that fluctuations or deviations of the supply voltage
"
from the nominal value always range within the permitted tole
rance limits (refer to technical data).
Capacitive or inductive interferences in the cables
Possibility of function disturbances!
"
Install the power lines and control cables separately.
The following clearances are recommended:
> 100 mm with parallel installation of cables < 10m,
> 250 mm with parallel installation of cables > 10m.
"
The product should be installed in close proximity to the welding
equipment in order to keep the lengths of the necessary connec
tion cords to a minimum.
Plugging or unplugging modules or connectors/terminals into/from
live systems
Possibility of damage to the electrical equipment, unexpected
plant reactions!
"
Unless described otherwise, never unplug or plug any connec
tors/terminals on live systems.
"
The timer's power supply should always be disconnected before
inserting/removing any timer modules.
PRC7000 |
NOTICE
R911172834 / 02