Mounting
Before mounting the drive components, observe the follow-
ing instructions:
▶ The drive components are designed for control cabinet
mounting.
This excludes drive components with a degree of protec-
tion of at least IP65 in accordance with IEC 60529 (e.g.,
KSM and KMS).
▶ Depending on the site of installation, the control cabinet
must provide sufficient protection against penetration of
foreign objects and ingress of liquids. The degree of pro-
tection must be at least IP54 in accordance with
IEC 60529.
▶ Ensure a safe location for the control cabinet.
▶ For installation and mounting, observe the additional
conditions (see index entries "Data", "Dimensions" and
"Installation" in the Operating Instructions).
WARNING
Personal injury during mounting work!
Danger by falling drive components.
▶ Use personal protective equipment (e.g. safety gloves,
safety shoes) and suitable mounting devices.
▶ When mounting drive components of a machine:
Before starting to work, secure the machine against
movements and unauthorized operation.
▶ Before unfastening mechanical connections, secure the
drive components against falling.

Electrical Connection

For information on the electrical connection of the drive
components, see the Operating Instructions (see index en-
tries "Connection points" and "Equipment grounding con-
ductor").
WARNING
High electrical voltage!
Danger to life, risk of injury by electric shock.
▶ Disconnect the mains power supply before accessing
the drive components and secure the mains power sup-
ply from reconnection.
▶ Before accessing the drive components, wait for the
drive components to discharge.
▶ Always operate drive components with a permanently in-
stalled equipment grounding conductor (= protective
grounding conductor).
In addition, observe the following instructions:
▶ The leakage current of the drive components is greater
▶ Observe the data on the type plate of the drive compo-
▶ Observe the data for the mains connection lines with re-
▶ Establish permanently safe electrical connections.
▶ Keep the control cabinets free from dust, dirt and mois-
▶ Only use original connection accessories by Rexroth.
Commissioning
High electrical voltage!
Danger to life, risk of injury by electric shock.
▶ Always operate drive components with a permanently in-
▶ Do not open protective coverings or protective housings
▶ Do not connect or disconnect electrical connections
Before commissioning, the following requirements must
have been fulfilled:
▶ The drive components are undamaged and free of dirt.
▶ The equipment grounding conductor has been perma-
▶ All electrical connections of the drive components were
▶ Fuses have been correctly installed and the Bb relay
DOK-DRIVE*-SAFETY*****-SA02-EN-P, R911339259, Edition 02, Bosch Rexroth AG
than 3.5 mA. Therefore, observe the requirements on
the minimum cross section of the equipment grounding
conductor (see "Equipment grounding conductor" in the
Operating Instructions).
nent and the connection diagram in the Operating In-
structions.
gard to the minimum cross section, installation method,
ambient temperature and insulation material (see Ope-
rating Instructions).
ture.
WARNING
stalled equipment grounding conductor.
when drive components conduct voltage.
when the electrical connections conduct voltage. For
this purpose, first disconnect the mains power supply
and secure the mains power supply from reconnection.
Before accessing a drive component, allow the compo-
nent to discharge within the time specified on the com-
ponent.
nently connected at all drive components (see "Equip-
ment grounding conductor" in the Operating Instruc-
tions).
checked (see index entry "Connection points" in the
Operating Instructions).
contacts have been wired.