10

DATA SHEET

10.1

TYPE

CLEAR DOS Dosing pump
10.2

TECHNICAL DATA

/
The water being dosed must comply with the European Drinking Water Directive.
/
The rated pressure indicates the pressure range that the dosing pump must comply with in accordance
with DIN EN 14812 and DIN 19635-100. The maximum operating pressure is lower to ensure the op-
timum function of the dosing pump.
Technical data
Connection diameter nominal
Working range according to DIN EN 14812 and DIN 19635-100:
Lower/upper working limit
Nominal pressure
Operating pressure
Pressure loss at upper working limit
Volume of the mineral solution container
Treated water volume per mineral solution container
Electrical connection
Power consumption: Operation
Threaded connection according to
Water and ambient temperature
Operating weight
Shipping weight
Dosing
CLEAR DOS
DN 25 / 1"
0.06 - 4 m³/h
PN 10
max. 8 bar
0.8 bar
6 litre
48 - 80 m³
230 V / 50 Hz
max. 2 W
max. 10 W
DIN EN 10226-1
max. 30 °C
Approx. 9.8 kg
Approx. 4.2 kg