A shut-off valve must be installed upstream of the dosing pump if no bypass valve is fitted. This allows
the water supply to be disconnected for dosing pump maintenance, repairs or if a fault occurs. Likewise
flooding and severe water damage to household furnishings and equipment can be avoided in this way.
/
The dosing pump must not be subject to severe impacts.
/
The device can be installed in all commercially available drinking water piping systems.
/
Installation of the dosing pump upstream of the water meter is forbidden.
A permanent power connection (230 V, 50 Hz) must be available.
A splashproof socket, complying with the legal regulations for wet areas, is re-
quired for the power supply unit.
5.3
PLACE OF INSTALLATION
Always install the dosing pump in an upright position (± 5°). If this is not observed,
the pump may not function correctly.
5.4
POWER SUPPLY
In the power supply unit the mains voltage is reduced to a safe low voltage of 24 V
which is then used to operate the system electronics. No other power supply units
shall be used!
The mains voltage must not be interrupted (e.g. via a light switch).
If the dosing pump does not have a permanent power connection,
/
dosing will not take place,
/
no error warnings will be output.
49