Pull the power supply unit out of the socket.
/
Disconnect the water supply to the dosing pump. Close the stopcock or switchover the bypass valve.
/
Protect the flange surfaces against damage! Damaged flange surfaces will no longer seal correctly. The
resulting escaping water can cause damage to the home and furnishings and equipment.
/
It must therefore be ensured that no dirt gets into the dosing pump. When the dosing pump is recom-
missioned, this dirt can come into contact with the drinking water and be released into it. The health of
persons drinking contaminated water is put at risk.
/
Store the dosing pump in a frost-free area. Frost can freeze water enclosed in the dosing pump, result-
ing in mechanical damage to the dosing pump. Escaping water can cause serious property damage in
the home.
/
Once the dosing pump is fitted and started again, it must be bled and flushed through.
Recommissioning sequence:
/
Open stopcock/bypass valve.
/
Open a tap downstream of the dosing pump. After a flushing water quantity of 5 l the dosing pump is
bled.
/
Plug the power supply unit in.
The dosing pump now automatically starts operating.
6.13

OVERVIEW OF DISPLAY MESSAGES

Indication
Minerallösung
Behälter leer
Wartung/
Service
Description
The message appears if the empty
signalling electrodes are dry.
It goes out as soon as a new mineral
solution container has been insert-
ed and the empty signalling elec-
trodes are again immersed in the
mineral solution.
The message appears after the an-
nual service interval has elapsed.
Further information
see chapter 6.7 "EXCHANGE OF THE MIN-
ERAL SOLUTION CONTAINER"
see chapter 9.3 "MESSAGE "MAINTE-
NANCE/SERVICE""