APPENDIX B: DEFAULT SELECTIONS FOR
OPTIONAL FACTORY SETTINGS
The table below provides the default settings for the parameters indicated:
Settings for maximum
input current
16A per phase
32A per phase
If these values do not apply to your situation, have the installer adjust the settings using the Service Installer application.
Modbus TCP/IP settings
In order for smooth communication with the smart meter through the Modbus TCP/IP, both need to be installed in the same
network. Before reading out all necessary data fields, the smart meter and the charging station need to be able to commu-
nicate. For that, the following settings are important:
Port: 502
IPv4 addresses (use fixed IP address),
assigned by the network operator

Factory settings

SCN-NetworkName
SCN-SocketID
SCN-SocketCount
SCN-AlternatingPeriod
SCN-TotalStaticCurrent
SCN-SocketSafeCurrent
SCN-PhaseMapping-1
SCN-PhaseMapping-2
SCN-TotalSafeCurrent
30
At the
Assumed
outlet
settings
Station-MaxCurrent
1 x 3.7kW
1 x 11kW
SmartMeter MaxCurrent
Station-MaxCurrent
1 x 7.4kW
1 x 22kW
SmartMeter-MaxCurrent
Options
Name of the SCN
Unique ID of a socket within an SCN. For a charging station
with two sockets, this identification represents socket 1.
The total amount of sockets in the SCN.
The alternating period used in the event of insufficient
capacity. This characteristic is automatically synchronised
between charging stations within an SCN.
The maximum available capacity available for the SCN in
amperes. This characteristic is automatically synchronised
between charging stations within an SCN.
This safety value is used as a fall-back in case a charging
station loses connection with the other stations. This
characteristic is automatically syn-chronised between
charging stations within an SCN.
Single feeder cable on the left Socket: This characteristic
shows how the charging station is connected to the
installation (phase shifts).
Attention! With double feeder cable: use SCN-
Phasemapping-2.
For single feeder cable on the Right Socket: This
characteristic shows how the charging station is connected
to the installation (phase shifts)
Used as a fall-back in case multiple charging stations loose
connection with the other stations. The total number of
active charging stations will be limited not to exceed the
SCN-TotalSafeCurrent. This characteristic is automatically
synchronised between charging stations within an SCN.
Active Load balancing
on 1-phase connection
16
25
32
40
Modbus address of the energy meter
Default gateway of the local network
Subnet mask of the local network
Eve Single Pro-line DE manual | Version 1.0 | February 2020
Active Load balancing
on 3-phase connection
16
25
32
35
Values
Maximum of 8 characters
0-99
Maximum 100
Maximum 65535 (seconds)
Default: 360
Default 200 A
Default 6.0 A
Default: 4
1= L1, 2= L2, 3 = L3,
4= L1L2L3, 5= L1L3L2,
6= L2L1L3, 7= L2L3L1,
8 = L3L1L2, 9 = L3L2L1
Other values are invalid.
Default: 4
1= L1, 2= L2, 3 = L3,
4=L1L2L3, 5= L1L3L2,
6= L2L1L3, 7= L2L3L1,
8 = L3L1L2, 9 = L3L2L1
Other values are invalid.
Default 32.0 A