2.6.7 Available memory
Charge passes
Transaction database
Logging for diagnostics
2.6.8 User circumstances
Operating temperature
Relative atmospheric humidity
Electrical safety class
Degree of protection (casing)
IK protection (mechanical impact)
Stand-by use
Environmental conditions
Electromechanical environmental
conditions
Mechanical environmental conditions
NOTICE!
Where products are exposed to the elements, the case can be subject to gradual aging of the material, which can result in
product discolouration over time. Therefore, wherever possible, place the product in a sheltered place to optimise the life
of the materials.
NOTICE!
The operating temperature assumes the ambient temperature of a product delivered in the default casing colour 'RAL9016' .
Direct exposure to sunlight may have an adverse effect on the temperature range.
The ambient temperatures in the table above refer to a
product in its default casing, colour RAL9016. Other
(darker) colours may have an adverse effect on the product.
If the product is exposed to lower or higher temperatures,
continuous operation cannot be guaranteed.
If temperatures exceed the maximum values, the charging
station will automatically decrease the charging current
Eve Single Pro-line DE manual | Version 1.0 | February 2020
Local list: approx. 800 charge passes (via the Backend)
White list: approx. 1,200 charge passes (local)
Approx. 1,500 transactions (of 4u with 15min Wh-metering values)
Approx. 45,000 lines
-25°C - 40°C
5 - 95 %
I
IP55
IK10
Pro-line: approx. 3.9 – 4.1W
•
Indoor use
•
Outdoor use
E2 according to the Measuring Instruments Directive (2014/32/EG)
M1 according to the Measuring Instruments Directive (2014/32/EG)
to decrease the internal temperature. This stabilises the
internal temperature and makes it less likely that a
transaction will be unexpectedly paused.
If the product is directly exposed to sunlight, the
automated temperature management may automatically
start below the maximum ambient temperature.
2. PRODUCT