3.
You may set-up your new device either directly
from your Behnke door intercom's internal
configurations keypad or remotely using a
telephone with DTMF dialling. On door inter-
com devices that come with number keypads
you may also use these for configuration
purposes. If necessary, the option for direct
configuration can be deactivated, leaving
remote configuration as the only option. To
enter set-up mode, you need to enter a four-
digit security code. The different settings are
changed via configuration step codes with an
individual code for each function to be set.
1. Enter set-up mode
Locally from your Behnke door intercom:
Press the * key (on the internal configura-
tions
keypad or from a number keypad) [beep] -
enter the security code
(default setting: 0000) [beep] [beep]
Remotely using a telephone with DTMF dial-
ling:
Call your Behnke door intercom
The device will answer the call with a [beep].
Press the * key within two seconds after the
beep (in case more than two seconds have
elapsed already, you may enter the set-up
menu by pressing the * key twice) [beep]
Enter the security code
(default: 0000) [beep] [beep]
42
2. Enter the configuration step code:
Enter the configuration step code
(cf. table page) [beep ] [beep]
Enter the desired parameter and confirm
with the # key [beep] [beep] [beep]
The different configuration steps do not need
to follow a certain order. Entering an improper
value while in set-up mode will result in the
device producing a darker, slightly longer er-
ror tone. After hearing the error tone, you may
continue set-up with the next configuration
step code. Set-up mode will be automatically
terminated after 30 seconds of inactivity.
3. Exit set-up mode
Press the * key or after 30 seconds of
inactivity.