10.6 Service kits

Warning
Before starting work on the pump, make sure that the fuses have been removed or the mains
switch has been switched off. Make sure that the power supply cannot be accidentally
switched on.
All rotating parts must have stopped moving.
The service kits in the table below are available for all SEG pumps.
The kits can be ordered as required:
Service kit
Contents
Shaft seal kit
Shaft seal complete
O-ring kit
O-rings and gaskets for oil screws
Grinder head, grinder ring, shaft screw
Grinder system
and locking screw
Impeller complete with adjusting nut,
Impeller
shaft screw and key
1 litre of oil, type Shell Ondina X420.
See section
Oil
service
chamber.
Lifting bracket
Lifting bracket and screw
*
For pumps produced in week 19, 2014: P.C. code 1419.
A possible replacement of the cable must be carried out by Grundfos or a service workshop
Note
authorised by Grundfos.

10.7 Contaminated pumps

Warning
If a pump has been used for a liquid
which is injurious to health or toxic, the
pump will be classified as
contaminated.
If Grundfos is requested to service the pump,
Grundfos must be contacted with details about the
pumped liquid, etc. before the pump is returned for
24
10. Maintenance and
for required quantity in oil
Pump type
Material
BQQP
SEG.40.09 - 15
BQQV
BQQP
SEG.40.26 - 40
BQQV
SEG.40.09 - 15
SEG.40.26 - 40
Heavy duty
applications
Standard
applications
SEG.40.09
SEG.40.12
SEG.40.15
SEG.40.26
SEG.40.31
SEG.40.40
All types
SEG.40.09 - 15
SEG.40.26 - 40
service. Otherwise Grundfos can refuse to accept
the pump for service.
Possible costs of returning the pump are paid by the
customer.
However, any application for service (no matter to
whom it may be made) must include details about
the pumped liquid if the pump has been used for
liquids which are injurious to health or toxic.
Before a pump is returned, it must be cleaned in the
best possible way.
Product number
96076122
96645160
96076123
96645275
96076124
NBR
98682327*
96646061
FKM
98682329*
NBR
96076125
FKM
96646062
96903344
96076121
96076115
96076116
96076117
96076118
96076119
96076120
96586753
96690420
96690428

Werbung

loading