6.

Installation of accessories

6.1

ITE pressure gauge

1. Prepare the tyre changer:
$ Disconnect the power and pneumatic;
$ Remove the side door;
2. Mount the support bracket of the electronic manom-
eter through the two screws provided with the tyre
changer;
3. Mount the electronic pressurre gauge to the bracket
through the two screws provided;
4. Open the grey box of the electrical connections;
5. Connect the supply cable coming from the pressurre
gauge;
6. Remove the control panel of the electronic pressurre
gauge and check on the internal transformer if the
connections are correct according to the kind of
power supply;
7. Connect the air tube coming from the pressurre
gauge on the VGP valve that is inside the tyre chang-
er;
8. Reclose the control panel of the pressurre gauge;
9. Reclose the side of the tyre changer.
Fig. 64:
Electronic pressure gage ITE
Robert Bosch GmbH
Installation of accessories | TCE 4460-TCE 4465 | 61
6.2

Kit storage

1. Prepare the tyre changer:
$ Disconnect the power and pneumatic supply;
$ Remove the side door;
2. Mount the support bracket of the group through the
two screws provided with the tyre changer;
3. Mount the drawers to the bracket through the two
screws provided;
4. Reclose the side door.
! Attention: the KIT STORAGE and MANOMETRO ITE
accessories are compatible because they use the
same support bracket