TOOLBOX
Identification of information display areas (Fig. 7)
- 19: Audio volume symbol
- 20: Screen brightness symbol
- 21: Light off time-out symbol
- 25: Relative audio volume value
- 26: Relative brightness level value
- 27: Selected time-out value
- 28: Software version
Identification of key areas (Fig. 7)
- 18: Reset factory configuration
- 22: Reduce value
- 23: Increase value
- 24: Validate the configuration
b) Control unit back panel
The power receptacle (Fig. 2-1) with its
grounding pin is used to connect the P
to the power supply using a plug-in power cord.
The footswitch connector (Fig. 2-2) is used to
connect the P
IEZOTOME
control footswitch.
The fan (Fig. 2-3) protected by a metal grille,
keeps the P
IEZOTOME
level.
The bracket holders (Fig. 2-4) are used to install
the brackets.
The power switch (Fig. 2-5) is used to switch the
device ON or OFF.
c) Control unit sides
The pump housings (Fig. 1-9) are designed to
accommodate SATELEC irrigation line cassettes.
The irrigation cassettes are installed by lifting
the pump covers and inserting the cassettes
horizontally into the cassette housings.
8
2 to the multifunction
2 at its optimum performance
d) Front panel
The two connectors are designed to accept the
connector of the N
the connector of the P
handpiece cord.
e) Control footswitch
The access to a large number of functions on the
control footswitch allows the practitioner to work
in a perfectly sterile environment, avoiding the
risk of cross-contamination.
Once the various settings have been adjusted,
the user has no further need to touch the keypad.
Depending on the mode, the control footswitch
buttons have different functions.
P
IEZOTOME
Footswitch button definition (Fig. 8)
2
- 1: Ultrasonics control (ON/OFF or progressive)
IEZOTOME
- 2: Flush/prime
- 3: Change program (D1 to D4)
- 4: Irrigation ON/OFF
- 5: Select active handpiece
N
EWTRON
Footswitch button definition (Fig. 8)
- 1: Ultrasonics control (ON/OFF or progressive)
- 2: Flush/prime
- 3: Change program (Soft to Boost)
- 4: Irrigation ON/OFF
- 5: Select active handpiece
f) Technical characteristics
Manufacturer: SATELEC
Device name: P
Electrical power supply:
- Voltage: 100 VAC to 230 VAC
- Frequency: 50 Hz/60 Hz
- Rated power: 150 VA at 230 VAC