Command Reference
Commands available from the
Multiplexer
ACK(0A)
Response when this unit receives a command.
NAK(0B)
Response if this unit did not receive the command.
ALARM(BF)
When there is an alarm, this command is sent as
header. Then, the alarm information is sent in a 1-byte
transmission (see Table 3).
Table 3 ALARM information
Bit
7
Alarm information
indication
6
5
Reserved
4
Reserved
3
Camera number
indication
2
1
0
66
(GB)
Bit state information
00: No alarm
01: External
10: Video loss
11: Sensor alarm
0
0
0000: CAMERA NO. 1
0001: CAMERA NO. 2
0010: CAMERA NO. 3
0011: CAMERA NO. 4
0100: CAMERA NO. 5
0101: CAMERA NO. 6
0110: CAMERA NO. 7
0111: CAMERA NO. 8
1000: CAMERA NO. 9
1001: CAMERA NO. 10
1010: CAMERA NO. 11
1011: CAMERA NO. 12
1100: CAMERA NO. 13
1101: CAMERA NO. 14
1110: CAMERA NO. 15
1111: CAMERA NO. 16