Function table DCA 650-02
DTMF
Function
dialing
0 - 9
Accept door call
9
Simplex mode
# 0
Abort connection
# 101
Change direct call number TLN1
# 102
Change direct call number TLN2
# 103
Change direct call number TLN3
# 21x
Switch DCSF relay 1
# 22x
Switch DCSF relay 2
# 23x
Switch DCSF relay 3
# 31
Scan DCSF input 1
# 32
Scan DCSF input 2
# 33
Scan DCSF input 3
# 41x
Concierge function on/off
# 50
Light
# 51
System control function 1
# 52
System control function 2
# 53
System control function 3
# 54
System control function 4
# 55
System control function 5
# 56
System control function 6
# 61
Door release
# 70
Selection of last calling door
# 71
Direct selection door 1
# 72
Direct selection door 2
# 73
Direct selection door 3
# 81x
Chain call function user 1 on/off
# 82x
Chain call function user 2 on/off
# 83x
Chain call function user 3 on/off
# 801
Change chain call number user 1
# 802
Change chain call number user 2
# 803
Change chain call number user 3
# 990
Switch off Doormatic function
# 991
Switch off Doormatic function
# 910
Function reset
*PIN*
PIN protection
PIN
Description
pro-
tection
An active door call through the DoorCom Analog
(= ID tone is injected) can be accepted by entering any
optional multiple frequency dialling character 0 - 9.
Only with an existing door call, the speech direction
is switched over with each „9". The simplex mode is
retained until the end of the call.
Deliberate termin. of a connection, e.g. when the TC
system doesn't signal an engaged tone at the end of a call
yes
Input at the telephone: #101+new call number +#
yes
Input at the telephone: #102+new call number +#
yes
Input at the telephone: #103+new call number +#
yes
x=1: Switch on, x=0: Switch off
yes
x=1: Switch on, x=0: Switch off
yes
x=1: Switch on, x=0: Switch off
Status 1 (energized) or 0 (not energized) is signalled by 2
different tones.
Ditto
Ditto
yes
x=1: Switch on, x=0: Switch off
Corresponds to pressing the light button at the BTS/BTC
yes
Assignment to a BSM/BSE must be programmed
yes
Ditto
yes
Ditto
yes
Ditto
yes
Ditto
yes
Ditto
Corr. to pressing the door release button at the BTS/BTC
Door assignment must be programmed
Ditto
yes
Ditto
x=1:Switch on chain call function user 1,
yes
x=0: switch off
x=1:Switch on chain call function user 2,
yes
x=0: switch off
x=1:Switch on chain call function user 3,
yes
x=0: switch off
yes
Input at the telephone: #801 +new call number +#
yes
Input at the telephone: #802 +new call number +#
yes
Input at the telephone: #803 +new call number +#
yes
For safety reasons, double input is required
The functions Doormatic, concierge and chain call 1 - 3
yes
are reset (switched off)
PIN entry when it is programmed in DCA 650,
yes
protection from unauthorized access
7