IFM Electronic Ecomot 100 Handbuch Seite 40

Datenspeicher/-logger für canopen-netzwerke
Vorschau ausblenden Andere Handbücher für Ecomot 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CAN
CR3101
MEM
Manufacturer-specific profiles, index 2000 to 5FFF (acc. to CiA DS 301)
Index
S-Idx
2010
0x00
1
Milliseconds
2
3
4
5
Day month
6
7
20F0
0x00
20F1
20F2
0x00
20F3
20F4
0x00
StartUp mode
20F5
0x00
Operating mode
Please note:
The entries 20F0/20F1 and 20F2/20F3 must always contain the same value.
Changes are effective after a reset (power off/on).
40
Name
Type
Date/Time
u8, rw
u16, rw
Seconds
u8, rw
Minutes
u8, rw
Hours
u8, rw
u8, rw
Month
u8, rw
Year
u8, rw
Node ID
u8, rw
setting
Baud rate
u8, rw
setting
CANopen
u8, rw
PDO
u8, rw
Default
Description
0x08
CANmem system time for time stamp.
The current values are entered before
delivery of the device.
The end user can change the values
(e.g. when changing to another time
zone).
--
Milliseconds
--
Seconds
--
Minutes
--
Hours
--
Day month
--
Month
--
Year
0x20
Node ID used to address CANmem
(= 32)
in the CANopen network
valid values: 1...127
0x03
Baud rate of the CAN system
0 = 1000 kBaud
1 = 500 kBaud
2 = 250 kBaud
3 = 125 kBaud (default)
4 = 100 kBaud
5 =
50 kBaud
6 =
20 kBaud
7 =
10 kBaud
0x00
CANmem StartUp Mode
0 = Pre-operational mode
Device must be switched into
operational mode
1 = Operational mode
Device starts automatically in
operational mode
0x00
PDO Operating Mode
0 = Logging Mode
1 = SD/MMC, PC card
PDO-Read Mode
(→ 10. Notes on programming
→ PDO handling)
2 = Low-Level
SD/MMC, PC card
PDO-Read access
(used only by CANmem
Configurator software)