CAN
CR3101
MEM
EMCY objects
The device supports the following EMCY objects:
EMCY code
Error reg
0x5000
0x81
0x5001
0x81
0x5002
0x81
0x6200
0x81
Data test
For files with default values/preset value tables a checksum is formed when the
files are created on the PC. This checksum is stored on the memory card.
With every power on or when the memory card is exchanged, the device calcu-
lates the checksum of the contents of these files and compares it with the check-
sum stored. If the two values do not match, an error message is given.
8. Operation indication
Status LED
CARD ERROR (red)
CARD ACCESS (green)
ON (green)
ERROR (red)
CAN (green)
In the initialisation phase (approx. 5 s) the LEDs indicate no defined state.
38
Additional code
Description
0x0000000000
"Device hardware"
LowBatt
0x000000000
"Device hardware"
An attempt was made to write or read
although no memory card was inserted.
0x0000000001
"Device hardware"
bis
For a file with preset values an error was
0x0000000010
found during a CRC check.
The number of the file 1...8 is transferred in
the additional code.
0x0000000001
"User software"
bis
For one of the files the memory limit
0x0000000010
was exceeded.
The number of the file 1...8 is transferred in
the additional code.
Status
Description
ON
Memory card error
ON
Memory card access active
OFF
Supply voltage missing
ON
Supply voltage ok
OFF
no fault
ON
CAN bus off
flashing
CAN bus error / other error
OFF
No relevant CAN object present
or CAN not active
or device not OPERATIONAL
ON / flashing
Device OPERATIONAL and relevant
CAN object detected