Faults in operating sequence
Description
Windows will no longer start on ac-
count of non-registration
FWA 46xx + only runs in Demo mo-
de.
No display and lamps in computer
and monitor do not light.
No display and lamp in computer
lights
Poor display quality
No remote control function
Batteries in sensor not or inade-
quately charged
No or poor record print-out
Tab. 4:
Fault and information messages
i
Explanatory notes on other fault messages can be called up in the Online Help by pressing the "Help button" or
the key F1.
|
1 690 706 098
2017-11-27
Possible cause
The Windows version was not registe-
red after installing Windows.
Dongle not plugged in.
No licence.
No power supply.
Switch set to Off.
Connecting cable defective.
Monitor switched off.
Brightness and contrast not proper-
ly set.
Cable connection defective.
Monitor defective.
Incorrect monitor setting.
Monitor or graphics card defective.
Path to unit obstructed.
Remote control battery flat.
"RemoteControlEx" program not star-
ted.
"RemoteControlEx" program incorrect-
ly configured.
Unit not permanently connected to
mains voltage.
Sensor contacts defective.
Fault in wiring.
Measurement box defective.
Printer switched off.
No paper in printer.
Ink cartridge empty.
Paper wrongly inserted in printer.
Defective wiring between printer and
computer.
Printer incorrectly set.
Printer and interface defective.
Remedy
Register Windows version via internet or by telephone.
Plug in dongle.
Perform licensing.
Check mains socket, mains fuse and mains connector
(charging station).
Set switch in trolley to On.
Replace connecting cable.
Switch on monitor (monitor switch).
Adjust brightness and contrast.
Check connector between monitor and computer and
replace cable if necessary.
Inform customer service.
Adjust brightness, contrast, height and position of dis-
play.
Inform customer service.
Alter position of remote control
(to avoid obstruction).
Fit new battery.
Start program.
Perform configuration as per Online Help.
Alter mains connection. Do not deactivate mains volta-
ge via master switch.
Make sure lamp lights when inserting sensors in char-
ging mounts on trolley.
Check wiring between measurement box and charging
contacts.
Inform customer service.
Switch on printer.
Insert fresh paper.
Replace ink cartridge.
Check paper guide.
Check wiring and connector to printer.
Install printer as per manual.
Inform customer service.