3.3

Sensors

3.3.1

Fitting and transportation

!
Transport with care.
Avoid impact on the sensors.
Take care not to drop the sensors.
!
The sensors must be in horizontal position on rai-
sing the platform.
i
Heed the notes on commissioning of the sensors
(refer to 1 690 706 102).
3.3.2

Connection

i
The sensors are assigned by way of the software.
i
There is a difference between left/right sensors. This
can be seen from the marking on the sensor.
2
Abb. 4:
Front view of sensor
1 Camera
2 Reference camera
1
2
Abb. 5:
Bottom view of sensor
1 PoE-Switch connection
2 Measurement box connection
Robert Bosch GmbH
1
1
Product description | FWA 46xx + | 31 | en
3.3.3

Important notes on operation

!
Check the sensors for condensation before swit-
ching on.
In the event of moisture, wait for the moisture on
the measuring device to evaporate.
!
The sensors must not be allowed to come into con-
tact with splashwater.
Provide the sensors with a water-proof cover when
cleaning.
!
On the platform the sensor is only to be folded up
for connection and disconnection.
i
Remove the sensors again on completion of measu-
rement.
i
The glass filters of the cameras are to be cleaned
at regular intervals with a clean, soft cloth (e.g. if
contaminated or moist).
3.4

Measurement board

1
Abb. 6:
Measurement board with plug-in stem
1 Plug-in stem
i
If dirty, clean the measurement boards with warm
water containing a small quantity of detergent (dab
only, do not rub or scour).
i
When in storage, brotect the measurement boards
against dust (recommendation: wall bracket for mea-
surement boards and clamp 1690701040).
|
1 690 706 098
2017-11-27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis