Communication interface
Integrated DC circuit breaker
Cooling principle
Test certificate
10.2 Radiation and temperature sensor
Type
General
Shunt resistor
Ambient temperature
Supply voltage
Current draw
Connecting cable
Cell dimension
Dimensions Length / Width / Height
Weight
Solar radiation
Measuring range
Output signal
Measuring accuracy
Module temperature
Measuring range
Output signal
Measuring accuracy
Nonlinearity
Max. deviation
Pin assignment
Orange
Red
Black
Brown
Supply voltage
748.508 | Z01 | 2013-06-10
RS485; Ethernet
yes, compliant with VDE 0100-712
natural convection
CE mark, certificate of compliance as per DIN VDE
0126-1-1, VDE AR N 4105, G59, AS4777, UTE C 15-
712-1, CEI 0-21, C10/C11
Si-13TC-T-K
0,10 Ω (TK = 22 ppm/K)
-20 °C to +70 °C
12 to 24 VDC
0,3 mA
4 x 0,14 mm², 3 m (UV-resistant)
50 mm x 34 mm
145 mm x 81 mm x 40 mm
0 to 1300 W/m²
0 to 10 V
±5% of final value
-20 °C to +90 °C
2.268V + T [°C]* 86.9 mV/°C
±1.5% at 25 °C
Output signal radiation (0 - 10 V)
Supply voltage (12 - 24 VDC)
Output signal temperature (0 - 10 V)
Temperature and radiation sensor or Power cap
340 g
0.5 °C
2 °C
GND
EN
57