Figure No. 24
The data of the Si-13TC-T-K can be called up with the following parameters:
D 1191.00 => incidence
 0–10 V => 0–1300 W/m²
D 1193.00 => temperature
 0–10 V => –26.1° C to 90° C
This data can also be recorded in the data logger.
Note:

8.3 Remote Monitoring System

The following options are available for remote monitoring:
Web Log: Data logger by MeteoControl. Connection via RS485.
SolarLog: Data logger by Solare Datensysteme. Connection via RS485.
Where MeteoControl and Solarlog are concerned, data is imported from the inverters via an RS485
interface.
For information about the configuration, please refer to the Operating Instructions of the particular
data logger.
748.508 | Z01 | 2013-06-10
Connection of the solar radiation sensor
If you do not use the temperature input, wire a jumper across PIN 4 and
PIN 5. Alternatively, you can also wire the jumper to the intermediate
terminal point (cable extension).