8.4 Instrument settings for monitoring with SolarLog

®
Control
All inverters have to be equipped with the firmware version RTF-80xR0xx-25-x-S or higher (avail-
able at: Menu F1/unit information/version identification/RFP ...).
The RS485 interface (RS485 IN / OUT) is standard on all inverter units.
For communication via SolarLog
Grid 230003 ph must be given a communications address. It is recommended to predefine the
addresses continuously starting with 1 (then 2, 3, etc. to max. 31).
Note:
These settings visible on the inverter control panel are to be carried out as follows:
Analysis
Actual values
Failure memory
Configuration
Device information
F1
F1-Menue
ESC
Protocol: for
SolarLog
or for MeteoControl
Note:

8.5 Data Logger Parameters

These parameters serve as settings for the internal data logger.
Parameter
Parameter name
number
P450.00
Data logger enabled
P451.00
Data logger interval
P452.00 - 39
Data logger parameter num-
bers
P453.00 - 39
Data logger indices
54
®
or Meteocontrol
The maximum number of inverters systems that can be operated at one
bus is 31.
Configuration
Languages
Communication
Date / Time
Portal settings
Extended
F1
Password
F1-Menue
ESC
©
enter „2"
,
enter „3"
After successful entry turn the inverter off and after 1 minute turn back on!
®
each StecaGrid 20000 3ph or Steca-
Configuration
Communication
Ethernet
RS485
F1
F1-Menue
ESC
F1
ESC
.
Description
Enables or disables the data logger.
0 = disabled.
1 = enabled. Data will be recorded at regular intervals.
Contains the time interval (60 / 300 / 600 sec) for which the
data logger stores values.
Contains a list of all parameter numbers to be recorded. This
only works in conjunction with indices (P453.x). Nonexistent pa-
rameter numbers will be ignored.
Contains a list of all indices assigned to the parameter numbers
to be recorded. This only works in conjunction with parameter
numbers (P452.x). Nonexistent parameter numbers will be ig-
nored.
®
or Meto-
Configuration
Communication
RS485
USS- address
Protocol
F1
F1-Menue
ESC
Configuration
Communication
RS485
USS- address
Protocol
F1
F1-Menue
ESC
748.508 | Z01 | 2013-06-10
USS- address
0
F1-Menue
Protocol
1
F1-Menue