2.7 Protection during handling and assembly

Danger of injury with improper handling through crushing, shearing, cut-
ting, striking and raising.
The weight of the inverter amounts to 40 kg!
 Follow the general instructions for assembly and safety whilst handling
 Use suitable assembly and transportation equipment.
 Avoid pinching and crushing by taking suitable precautions.
 Only use suitable tools. Use special tools where this is prescribed.
WARNING
 Use lifting equipment and tools in a technically correct manner.
 If necessary, use suitable protective equipment (for example, goggles,
 Do not stand under hanging loads.
 Remove any liquids escaping onto the floor immediately to avoid the dan-

2.8 Note before starting up

In the event of installation in France, the device must be provided with the warning sticker laid
down by UTE C 15-712-1. The warning sticker is included in the delivery.
Problem-free and safe operation of the inverter is conditional upon due and specialised trans-
portation, storage, assembly and installation as well as careful operation and maintenance.
Only use accessories and spare parts approved by the manufacturer.
Adherence must be ensured to the prescriptions and stipulations regarding safety of the coun-
try in which the inverter is to be used.
The environmental conditions stated in the product documentation must be observed.
Starting up is to be prohibited until the entire equipment corresponds to the national stipula-
tions and safety rules regarding use.
Operation is only permitted with adherence to the national EMC prescriptions for the present
use case.
The manufacturer of the equipment or machine is responsible for ensuring adherence to the
thresholds required by the respective national stipulations.
European countries: EC Directive 2004/108/EC (EMC Directive).
The inverter complies with the EN 61000-3-11, when connected to a grid connection point with
a maximum line impedance of 0.26 ohms.
The technical data, connection and installation conditions are to be taken from the product
documentation and must be observed under all circumstances.
Switching off of the inverter must first be effected on the AC side via the circuit breaker. Switch-
off is then to be effected on the DC side via the DC circuit breaker, should maintenance work
need to be carried out on the DC side. This ensures the life expectancy of the DC circuit
breaker is increased.