Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha RX-V1800 Bedienungsanleitung Seite 94

Vorschau ausblenden Andere Handbücher für RX-V1800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 278
Customizing this unit (MANUAL SETUP)
When the speakers in Zone 2 or Zone 3 is
connected to the SP2 speaker terminals of this
unit directly:
Select "[SP2]". See "Using the internal amplifiers of
this unit" on page 109 for details.
Note
When you set "AMP" to "[SP2]" in "ZONE 2" or "ZONE
3" and the corresponding zone is turned on, no sound is
output from the surround speakers.
If the speakers in Zone 2 or Zone 3 are
connected to both the SP1 and SP2 speaker
terminals (for example, the speakers are
connected via the bi-amplifier connection, or
there are four speakers in a room) or if you
want to play back the same source in Zone 2
and Zone 3 simultaneously:
Select "BOTH". See "Using the internal amplifiers of
this unit" on page 109 for details.
Notes
• When you set "AMP" to "BOTH" in "ZONE 2" or
"ZONE 3", you can only set "AMP" to "EXT" in the other
zone setting.
• When you set "AMP" to "BOTH" in "ZONE 2" or
"ZONE 3" and the corresponding zone is turned on, no
sound is output from both the surround and surround back
speakers.
92
En
Zone 2/Zone 3 volume VOLUME
Use this feature to select whether this unit controls the
volume level of the audio signals output at the ZONE
OUT (ZONE 2 or ZONE 3) jacks when you set "AMP" to
"EXT" (see page 91).
Choices: VAR, FIX
When you want to control the volume level of
the selected zone on this unit:
Select "VAR". You can adjust the ZONE OUT (ZONE
2 or ZONE 3) volume level simultaneously with
B VOLUME +/– on the remote control.
When you want to control the volume level of
the selected zone on the external amplifier:
Select "FIX". This unit fixes the ZONE OUT (ZONE 2
or ZONE 3) volume level to a standard line level.
Zone 2/Zone 3 maximum volume MAX VOL.
Use this feature to set the maximum volume level in the
Zone 2 or Zone 3.
Control range: –30.0 dB to +15.0 dB, +16.5 dB
Control step: 5.0 dB
Note
The "MAX VOL." setting takes priority over the "INIT. VOL."
setting. For example, "INIT. VOL." is set to –20.0 dB and then
"MAX VOL." is set to –30.0 dB, the volume level is
automatically set to –30.0 dB when you turn on the power of this
unit next time.
Zone 2/Zone 3 initial volume INIT. VOL.
Use this feature to set the volume level of Zone 2 or Zone
3 when the power of Zone 2 or Zone 3 is turned on.
Choices: OFF, MUTE, –80.0 dB to +16.5 dB
Control step: 0.5 dB
Note
The "MAX VOL." setting takes priority over the "INIT. VOL."
setting.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis